An interoperability error occurred with entity . A presentation error occurred. ASN.1 decode failure. Server error code was detected at offset . Node label , Control block index . [ ]. (14)

Details
Product: Exchange
Event ID: 1192
Source: MSExchangeMTA
Version: 6.5.6940.0
Component: Microsoft Exchange Message Transfer Agent
Message: An interoperability error occurred with entity <object name>. A presentation error occurred. ASN.1 decode failure. Server error code <error code> was detected at offset <value>. Node label <name>, Control block index <index name>. [<value> <value> <value> <value>]. (14)
   
Explanation

This event typically occurs in Exchange 5.x Server environments when a message transfer agent (MTA) has been configured with a password on the General tab of the MTA property page. This is the password that foreign systems use when they connect to this (local) MTA.

   
User Action

To resolve this problem, configure the X.400 connectors in each site to pass the remote MTA password by entering the remote MTA password on the General tab of the property pages of each X.400 connector. If necessary, re-enter the values on both the MTA and X.400 connector, and then restart both the directory service and MTA service.