An RPC communications error occurred. An attempt to listen over RPC has failed. Windows 2000 Error: . [ ] (14)

Details
Product: Exchange
Event ID: 9321
Source: MSExchangeMTA
Version: 6.5.6940.0
Component: Microsoft Exchange Message Transfer Agent
Message: An RPC communications error occurred. An attempt to listen over RPC has failed. Windows 2000 Error: <error code>. [<value> <value> <value> <value> <value>] (14)
   
Explanation

A remote procedure call (RPC) communications error could be a symptom that the message transfer agent (MTA) was shut down. Check the status of the MSExchangeMTA service. Check Event Viewer for related problems.

An RPC communications error could be a symptom that the MTA was shut down.

   
User Action
  • At the Windows 2000 command prompt, use the Net Helpmsg command to determine the reason for the Windows 2000 error.
  • In Control Panel, double-click the Administrative Tools icon, double-click the Services icon, and then verify that the Remote Procedure Call (RPC) service is running.
  • Use Network Monitor to capture network traces, then view these traces from Network Monitor for any network issue.
  • If the error persists, double-click the Administrative Tools icon in Control Panel. Double-click the Services icon, and then stop and restart the Microsoft Exchange MTA Stacks service. If the error persists, check the TCP/IP binding order.

Related: