The File Replication Service has detected an enabled disk write cache on the drive containing the directory %2 on the computer %1. The File Replication Service might not recover when power to the drive is interrupted and critical updates are lost.

Details
Product: Windows Operating System
Event ID: 13512
Source: NtFrs
Version: 5.2
Symbolic Name: EVENT_FRS_DISK_WRITE_CACHE_ENABLED
Message: The File Replication Service has detected an enabled disk write cache
on the drive containing the directory %2 on the computer %1.
The File Replication Service might not recover when power to the
drive is interrupted and critical updates are lost.
   
Explanation

The File Replication service detected an enabled disk write cache. Critical updates might be lost if the power to the drive is interrupted.

   
User Action

To leave write caching enabled for improved performance and to ensure the integrity of the FRS jet database, use an uninterrupted power supply (UPS) or a disk controller and cache with a battery backup. Otherwise, disable write caching until you can install a backup power supply.