An MTA database server error was encountered while removing an entry from a queue. Called from {directory name}. Procedure {name}. Database error code: {error code}. Queue name: {name}. Object at fault: {object name}. [{value}{value}{value}{value}] (12)

Details
Product: Exchange
Event ID: 2192
Source: MSExchangeMTA
Version: 6.0
Component: Message Transfer Agent
Symbolic Name: MTA02192
Message: An MTA database server error was encountered while removing an entry from a queue. Called from {directory name}. Procedure {name}. Database error code: {error code}. Queue name: {name}. Object at fault: {object name}. [{value}{value}{value}{value}] (12)
   
Explanation
The message transfer agent (MTA) encountered an internal processing error while processing a message or report object. This indicates a logic error or database integrity failure.
   
User Action
This event ID is normal during work queue integrity checking after restart, in which case it is logged with the qualifier 118. Otherwise, to help Microsoft Product Support Services track down the problem, create log files. For more information, see Knowledge Base article Q163032. To create Ap*.log files, in the Server Properties dialog box, on the Diagnostics Logging tab, select MSExchangeMTA, and then set the logging level of the Interoperability and Interface categories to Maximum. To create Bf*.log files, set the logging level of the APDU and X.400 categories to Maximum.Save all MTA log files (mtadata\*.log), Event Viewer output, and database files. Contact Microsoft Product Support Services.You can enable text event log files (Ev*.log) by modifying the Registry. Contact Microsoft Product Support Services for assistance.