Details | |
Product: | Windows Operating System |
Event ID: | 4227 |
Source: | Wins |
Version: | 5.0 |
Component: | System Event Log |
Symbolic Name: | WINS_EVT_CANT_FIND_ANY_REC_IN_RANGE |
Message: | The Push Thread was requested for a range of records but could not find any records in the range. Make sure that the replication time intervals are set properly. If the tombstone interval and timeout intervals are not correct (that is, much less than the replication interval), the above condition is possible. This is because the records might get changed into tombstones and then deleted before the remote WINS can pull them. Similarly, if the refresh interval is set to be much less than the replication interval then the records could get released before a WINS can pull them (a released record is not sent). Make sure that the replication time intervals are set properly. |
Explanation | |
If the tombstone interval and timeout intervals are not correct (for example,, too small; being significantly less than the replication interval), this error occurs. This is because the records might get changed into tombstones and then deleted before the remote WINS can pull them. In the same way, if the refresh interval is set at too great of a replication interval, the records could get released before a WINS can pull them (a released record is not sent). |
|
User Action | |
To check and correct WINS interval settings: 1. Open Administrative Tools and then open WINS. |