XenMobile/Endpoint Management: Cloud Gear Icon returning “this page isn’t working HTTP ERROR 400”

Description:

error “this page isn’t working HTTP ERROR 400” may be displayed when trying to access the Cloud XenMobile / Endpoint Management Client instance when customers go to their own xxxx.xm.cloud and then click on the Could Gear Icon from the green tool bar at the top

User-added image

Doing so, will return “this page isn’t working HTTP ERROR 400”

User-added image

Solution:

It was confirmed the actual recommended method for all customers to access the XenMobile / Endpoint Management Console is via https://citrix.cloud.com

Related:

  • No Related Posts

Storefront upgrade from fails from 3.12 to 3.14 – 'CitrixStoreFront-x64.exe' component failed to install with error 0x00000643

Storefront upgrade from fails from 3.12 to 3.14 – ‘CitrixStoreFront-x64.exe’ component failed to install with error 0x00000643

These lines appear in the logs.

09:11:45.4298 : XenDesktopSetup:Starting synchronous process ‘C:tempCitrix_Virtual_Apps_and_Desktops_7_1808_2x64StoreFrontCitrixStoreFront-x64.exe’ with args ‘-silent -WINDOWS_CLIENT “C:tempCitrix_Virtual_Apps_and_Desktops_7_1808_2Citrix Receiver and Plug-insWindowsReceiverCitrixWorkspaceApp.exe” -INSTALLDIR “C:Program FilesCitrixReceiver StoreFront”‘

09:12:57.1065 : XenDesktopSetup:Process completed with error code 0x00000643

09:12:57.1085 $ERR$ : XenDesktopSetup:InstallComponent: Failed to install component ‘StoreFront’. ‘CitrixStoreFront-x64.exe’ component failed to install with error 0x00000643.

09:12:57.1085 $ERR$ : XenDesktopSetup:Recording installation failure. ‘CitrixStoreFront-x64.exe’ component failed to install with error 0x00000643.

09:12:57.1085 PROC : XenDesktopSetup:InstallComponent: Exit

09:12:57.1085 : XenDesktopSetup:Install tasks for this session have finished.

Related:

  • No Related Posts

Workspace App for Windows – Error “Cannot start app” intermittently

In Receiver’s error file you will find following message:

Launch error code: 3

Error launching the ICA file

Unable to launch using CCM (url)

at Dazzle.LaunchUtils.ICALaunchUtils.LaunchViaFile(String quotedIcaFilePath, String cmdline, String url)

Create the following exclusions for Imprivata hooking files in the client/end point registry:

[HKEY_LOCAL_MACHINESOFTWAREWow6432NodeSSOProviderISXAgentHookInit]

“Concentr.exe”=””

“SelfService.exe”=””

“AuthManSvr.exe”=””

“Receiver.exe “=””

“SelfServicePlugin.exe”=””

“wfcrun32.exe”=””

Related:

  • No Related Posts

Unable to Launch Citrix Studio to Access XenDesktop Site: “The License Server Has Been Upgraded”

ISSUE:

Unable to launch Citrix Studio to access XenDesktop Site. Following message appears: “The license server has been upgraded” and Studio prompts for a Site upgrade.

When running through the upgrade, the following error appears:

“The Service Instance is already registered with the Central Configuration Service”

Related:

  • No Related Posts

Cloud Gear Icon returning “this page isn't working HTTP ERROR 400”

Description:

error “this page isn’t working HTTP ERROR 400” may be displayed when trying to access the Cloud XenMobile / Endpoint Management Client instance when customers go to their own xxxx.xm.cloud and then click on the Could Gear Icon from the green tool bar at the top

User-added image

Doing so, will return “this page isn’t working HTTP ERROR 400”

User-added image

Solution:

It was confirmed the actual recommended method for all customers to access the XenMobile / Endpoint Management Console is via https://citrix.cloud.com

Related: